AquisNet DMO

Alarm Configuration

Scroll PDF |

You can configure alarm configurations to be used when working with the KISTERS AlarmManager (KiALM). For this, you specify a threshold value for each base production time series (not for aggregated time series!) to be monitored; if the time series values exceed or fall below this threshold, an alarm is triggered. During data import, the system checks whether alarm thresholds need to be monitored.

Start Alarm Limits from the Import > Interface main menu.

tceq_alarmconfig_all_zoom50

Add new alarm configurations for your time series with the context menu item Add.

For each alarm setting, specify:

Element

Description

Filter

In case of long lists of time series, filter the time series by their names.

Time Series

Select the time series for which you want to trigger alarms.

Receiver List

Select a receiver list.

These lists are used in the KISTERS AlarmManager (KiALM to send alarms to certain receivers by e.g. email. This list is transferred to the KISTERS AlarmManager (KiALM) together with the alarm data in XML format.

Function

Here you select the operator to be used for the alarm condition. Select e.g. equal to/smaller than or larger than.

Low Limit

Specify the time series value that will trigger a low-level alarm according to the selected operator. If your time series values are e.g. larger than the value specified here, a low-level alarm is triggered.

Medium Limit

Specify the time series value that will trigger a medium-level alarm according to the selected operator.

High Limit

Specify the time series value that will trigger a high-level alarm according to the selected operator.

Note: You do not need to specify all limit levels.

Save new alarm configurations with [OK].

Documented software version: 4.6.2