Non-moving and Moving Mean Value Generation |
Scroll
|
|
1 Non-moving mean value generation means that the mean value is calculated every n hours over the past n hours: Example for "3 h non-moving":
Value: Integration time from 0:00 to 3:00, assignment to 3:00
Value: Integration time from 3:00 to 6:00, assignment to 6:00 [...] This form of mean value generation is used for the half-hourly MW in the measuring station (✇ Evaluations, availability) 2 Moving mean value generation means that the mean value is calculated every half hour over the past n hours. Example for "3 h moving":
Value: Integration time from 21:30 of the previous day to 0:30, assignment of the value to 0:30.
Value: Integration time from 22:00 of the previous day to 1:00, assignment of the value to 1:00 [...].
48. Value: Integration time from 21:00 to 24:00, assignment of the value to 24:00.